[ANY-002]What is the procedure for replacing the control panel?

To replace the control panel in the ANY-002 printer, follow these steps:

  1. Power Off the Printer:
    • Ensure the printer is turned off and unplugged from the power source to avoid any risk of electric shock.
  2. Open the Top Cover:
    • Press the top cover release button to open the top cover of the printer.
  3. Remove the Control Panel:
    • Insert a flathead screwdriver into the slits on the upper side of the control panel to disengage the claws holding the control panel in place.
    • Carefully remove the connector and take the control panel assembly out.
  4. Install the New Control Panel:
    • Connect the new control panel assembly by attaching the connector.
    • Align the control panel assembly with the slits and press it into place until the claws engage securely.
  5. Close the Top Cover:
    • Close the top cover and ensure it is securely latched.

→ For detailed instructions, please refer to the relevant sections of the "[ANY-002] Maintenance Manual (error code, part replacement).pdf".